ZW4006 / GE26931 In-Wall Smart Motion Switch
This describes the Z-Wave device ZW4006 / GE26931, manufactured by Jasco Products with the thing type UID of ge_zw4006_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The ZW4006 / GE26931 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Overview
The switch enables wireless control of On/OFF functions of incandescent, LED, xenon, halogen and fluorescent lighting. Not only does it act as a switch but the GE In-Wall Smart Motion Switch has a built in PIR sensor which can control the local and be set in occupancy or vacancy mode.
Inclusion Information
- Follow the instructions for your Z-Wave certified controller to include the smart switch to the Z-Wave network.
- Once the controller is ready to include your smart switch, press and release the top or bottom button on the smart switch to include it in the network.
Exclusion Information
- Follow the instructions for your Z-Wave certified controller to exclude a device from the Z-Wave network.
- Once the controller is ready to exclude your device, press and release the top or bottom button on the smart switch to exclude it from the network.
General Usage Information
Channels
The following table summarises the channels available for the ZW4006 / GE26931 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch [Deprecated] | switch_binary | switch_binary | Switch | Switch |
Scene Number | scene_number | scene_number | Number | |
Binary Sensor | sensor_binary | sensor_binary | Switch | |
Motion Sensor Enable | config_decimal | config_decimal | Number | |
Operation Mode | config_decimal | config_decimal | Number | |
Motion Alarm [Deprecated] | alarm_motion | alarm_motion | Motion | Switch |
Switch 1 | switch_binary1 | switch_binary | Switch | Switch |
Motion Alarm | alarm_motion2 | alarm_motion | Motion | Switch |
Switch [Deprecated]
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Note: This channel is marked as deprecated so should not be used.
Scene Number
Triggers when a scene button is pressed.
The scene_number
channel is of type scene_number
and supports the Number
item.
Binary Sensor
Indicates if a sensor has triggered.
The sensor_binary
channel is of type sensor_binary
and supports the Switch
item. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Triggered |
OFF | Untriggered |
Motion Sensor Enable
Generic class for configuration parameter.
The config_decimal
channel is of type config_decimal
and supports the Number
item.
Operation Mode
Sets how the light responds to motion
1=Manual, 2=Vacancy, 3=Occupancy
Generic class for configuration parameter.
The config_decimal
channel is of type config_decimal
and supports the Number
item.
Motion Alarm [Deprecated]
Indicates if a motion alarm is triggered.
The alarm_motion
channel is of type alarm_motion
and supports the Switch
item and is in the Motion
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Note: This channel is marked as deprecated so should not be used.
Switch 1
Switch the power on and off.
The switch_binary1
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Motion Alarm
Indicates if a motion alarm is triggered.
The alarm_motion2
channel is of type alarm_motion
and supports the Switch
item and is in the Motion
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Device Configuration
The following table provides a summary of the 10 configuration parameters available in the ZW4006 / GE26931. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Timeout Duration | Amount of time the light stays on after motion stops |
2 | Dim level | Change brightness of associated light bulb(s) |
3 | Operation Mode | |
4 | Association Mode | Enable/Disable Association Mode |
5 | Invert Switch | In a 3-way configuration, invert the connected Add-On Switch buttons |
6 | Motion Sensor | Enable/Disable Motion Sensor |
13 | Motion Sensor Sensitivity | Amount of motion required to turn on the light |
14 | Light Sensing | Enable/Disable whether motion sensor only turns light on if room is dark |
15 | Reset Cycle | |
19 | Exclusion Mode | |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Parameter 1: Timeout Duration
Amount of time the light stays on after motion stops
The following option values may be configured -:
Value | Description |
---|---|
0 | Test (5s) |
1 | One minute |
5 | Five minutes |
15 | Fifteen minutes |
30 | Thirty minutes |
255 | Disable timeout |
The manufacturer defined default value is 5
(Five minutes).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Parameter 2: Dim level
Change brightness of associated light bulb(s)
The following option values may be configured -:
Value | Description |
---|---|
255 | Default |
The manufacturer defined default value is 255
(Default).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Parameter 3: Operation Mode
The following option values may be configured -:
Value | Description |
---|---|
1 | Manual |
2 | Vacancy |
3 | Occupancy |
The manufacturer defined default value is 3
(Occupancy).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Parameter 4: Association Mode
Enable/Disable Association Mode
The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled |
1 | Enabled |
The manufacturer defined default value is 1
(Enabled).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Parameter 5: Invert Switch
In a 3-way configuration, invert the connected Add-On Switch buttons
The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled |
1 | Enabled |
The manufacturer defined default value is 0
(Disabled).
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Parameter 6: Motion Sensor
Enable/Disable Motion Sensor
The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled |
1 | Enabled |
The manufacturer defined default value is 1
(Enabled).
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
Parameter 13: Motion Sensor Sensitivity
Amount of motion required to turn on the light
The following option values may be configured -:
Value | Description |
---|---|
1 | High |
2 | Medium |
3 | Low |
The manufacturer defined default value is 2
(Medium).
This parameter has the configuration ID config_13_1
and is of type INTEGER
.
Parameter 14: Light Sensing
Enable/Disable whether motion sensor only turns light on if room is dark
The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled |
1 | Enabled |
The manufacturer defined default value is 1
(Enabled).
This parameter has the configuration ID config_14_1
and is of type INTEGER
.
Parameter 15: Reset Cycle
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | 10 secs |
2 | 20 secs |
3 | 30 secs |
4 | 45 secs |
110 | 27 mins |
The manufacturer defined default value is 2
(20 secs).
This parameter has the configuration ID config_15_1
and is of type INTEGER
.
Parameter 19: Exclusion Mode
The following option values may be configured -:
Value | Description |
---|---|
0 | Normal |
1 | Alternate |
The manufacturer defined default value is 0
(Normal).
This parameter has the configuration ID config_19_1
and is of type INTEGER
.
Switch All Mode
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association Groups
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZW4006 / GE26931 supports 3 association groups.
Group 1: Lifeline
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Z-Wave Plus Lifeline
Association group 1 supports 5 nodes.
Group 2: Basic Set Local Load
Supports Basic Set and is controlled with the local load
Association group 2 supports 5 nodes.
Group 3: Basic Set Buttons
Supports Basic Set and is controlled by pressing the On or Off buttons
Association group 3 supports 5 nodes.
Technical Information
Endpoints
Endpoint 0
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_SCENE_ACTIVATION_V1 | |
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1 | |
COMMAND_CLASS_SENSOR_BINARY_V1 | |
COMMAND_CLASS_CRC_16_ENCAP_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_MULTI_CHANNEL_V2 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V4 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 |
Endpoint 1
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 |
Endpoint 2
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_ALARM_V4 | Linked to BASIC |
Documentation Links
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.