BE469ZP Touchscreen Deadbolt Z-Wave Plus

This describes the Z-Wave device BE469ZP, manufactured by Allegion with the thing type UID of schlage_be469zp_00_000.

The device is in the category of Lock, defining Devices whose primary pupose is locking something.

BE469ZP product image

The BE469ZP supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

Overview

Touchscreen Deadbolt with Alarm

Inclusion Information

One-button Add lock to Z-Wave Network (Inclusion) 1.Place your home automation system or panel into the Add or Inclusion Mode (Refer to the respective documentation for that specific home automation system or panel device for details). 2.Remove the battery cover of the deadbolt. 3.Press then release the button on the PCB.4.An LED will flash amber indicating the Add or Inclusion process is in progress. If the Security Scheme is Security 2 (S2), verify the DSK of the lock at the Z-Wave Controller. The PIN Code portion of the Z-Wave DSK will be needed.5.When a green LED turns ON, the Add or Inclusion has completed successfully. 6. If a red LED turns ON, try repeating steps 1-3

Interactive Instruction for Add https://instructions.allegion.com/instr/86/2543

Exclusion Information

One-button Remove lock from Z-Wave Network (Exclusion) 1.Place your home automation system or panel into the Remove or Exclusion Mode (Refer to the respective documentation for that specific home automation system or panel device for details). 2.Remove the battery cover of the deadbolt. 3.Press then release the button on the PCB. 4.An LED will flash amber indicating the Remove or Exclusion process is in progress. 5.When a green LED flashes 3 times, the Remove or Exclusion process is completed successfully. 6. If a red LED turns ON, try repeating steps 1-3

Interactive Instruction for Remove https://instructions.allegion.com/instr/86/2581

Channels

The following table summarises the channels available for the BE469ZP -:

Channel Name Channel ID Channel Type Category Item Type
Door Lock lock_door lock_door Door Switch
Electronic Transition Count config_decimal config_decimal Number
Mechanical Transition Count config_decimal config_decimal Number
Electronic Failed Count config_decimal config_decimal Number
High Preload Transition Count config_decimal config_decimal Number
Alarm (raw) alarm_raw alarm_raw String
Battery Level battery-level system.battery_level Battery Number

Door Lock

Lock and unlock the door.

The lock_door channel is of type lock_door and supports the Switch item and is in the Door category. The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Locked
OFF Unlocked

Electronic Transition Count

Electronic Transition Count

Generic class for configuration parameter.

The config_decimal channel is of type config_decimal and supports the Number item.

Mechanical Transition Count

Mechanical Transition Count

Generic class for configuration parameter.

The config_decimal channel is of type config_decimal and supports the Number item.

Electronic Failed Count

Electronic Failed Count

Generic class for configuration parameter.

The config_decimal channel is of type config_decimal and supports the Number item.

High Preload Transition Count

Electrical High Preload Transition Count

Generic class for configuration parameter.

The config_decimal channel is of type config_decimal and supports the Number item.

Alarm (raw)

Provides the raw alarm status information as a string, including alarm type and level, in the following json format: {"notification":"ACCESS__MANUAL_LOCK", "type":"ACCESS_CONTROL","event":"1","status":"255"} {"notification":"ACCESS__MANUAL_UNLOCK", "type":"ACCESS_CONTROL","event":"2","status":"255"} {"notification":"ACCESS__KEYPAD_LOCK", "code":"1", "type":"ACCESS_CONTROL","event":"5","status":"255"} {"notification":"ACCESS__KEYPAD_UNLOCK","code":"1", "type":"ACCESS_CONTROL","event":"6","status":"255"} {"notification":"ACCESS__LOCK_JAMMED", "type":"ACCESS_CONTROL","event":"11","status":"255"} {"notification":"ACCESS__KEYPAD_LOCK", "type":"ACCESS_CONTROL","event":"5","status":"255"} {"notification":"ACCESS_CONTROL\_KEYPAD_TEMPORARILY_DISABLED", "type":"ACCESS_CONTROL","event":"16","status":"255"} {"notification":"BURGLAR\_TAMPER_UNKNOWN", "type":"BURGLAR","event":"2","status":"255"} {"notification":"HOME_SECURITY__INTRUSION_UNKNOWN", "type":"BURGLAR","event":"2","status":"255"} {"notification":"POWER\_REPLACE_BATTERY_SOON", "type":"POWER_MANAGEMENT","event":"10","status":"255"} {"notification":"POWER_MANAGEMENT_REPLACE_BATTERY_SOON", "type":"POWER_MANAGEMENT","event":"10","status":"255"}

Provides alarm parameters as json string.

The alarm_raw channel is of type alarm_raw and supports the String item. This is a read only channel so will only be updated following state changes from the device. This channel sets, and provides the alarm state as a JSON string. It is designed for use in rules.

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The system.battery-level channel is of type system.battery-level and supports the Number item and is in the Battery category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.

Device Configuration

The following table provides a summary of the 16 configuration parameters available in the BE469ZP. Detailed information on each parameter can be found in the sections below.

Param Name Description
3 Beeper Keypad beeper to be turned ON or OFF
4 Vacation Mode Vacation Mode
5 Lock and Leave Mode Controls button push for throwing the deadbolt.
6 User Slot Bit Field Occupied slots for User Codes
7 Alarm Mode Lock Specific Alarm Mode
8 Alarm Alert Sensitivity Lock Specific Alarm Alert Sensitivity
9 Alarm Tamper Sensitivity Lock Specific Alarm Tamper Sensitivity
10 Alarm Kick Sensitivity Lock Specific Alarm Kick Sensitivity
11 Alarm Disable Local Controls Lock Specific Alarm Disable Local Controls
12 Electronic Transition Count Get Electronic Transition Count
13 Mechanical Transition Count Get Mechanical Transition Count
14 Electronic Failed Count Get Electronic Failed Count
15 Auto Lock Automatically throws the deadbolt 30 after seconds
16 User Code PIN Length Required length of all User Codes
17 Get Electrical High Preload Transition Count Count of high preload on the deadbolt
18 Get Bootloader Version Bootloader Version
Lock Timeout Sets the time after which the door will auto lock

Parameter 3: Beeper

Keypad beeper to be turned ON or OFF This configuration setting controls the keypad beeper of the deadbolt allowing the keypad beeper to be turned ON or OFF  The following option values may be configured -:

Value Description
0 Disable Beeper
255 Enable Beeper

The manufacturer defined default value is 0 (Disable Beeper).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Vacation Mode

Vacation Mode This configuration setting controls the keypad entry of User Codes allowing all User Codes to be turned ON (disable Vacation Mode) or OFF (enable Vacation Mode) The following option values may be configured -:

Value Description
0 Disable Vacation Mode
255 Enable Vacation Mode

The manufacturer defined default value is 0 (Disable Vacation Mode).

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Lock and Leave Mode

Controls button push for throwing the deadbolt. This configuration setting controls the use of the u0022Schlageu0022 button on the keypad for single button push for throwing the deadbolt.  The following option values may be configured -:

Value Description
0 Disable Lock and Leave Mode
255 Enable Lock and Leave Mode

The manufacturer defined default value is 0 (Disable Lock and Leave Mode).

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: User Slot Bit Field

Occupied slots for User Codes This configuration setting indicates the occupied slots (from 1 to 30) that contain User Codes that will activate the deadbolt when entered on the keypad.

Byte 1 (msb): Bit 7: User 8 Status Bit 6: User 7 Status Bit 5: User 6 Status Bit 4: User 5 Status Bit 3: User 4 Status Bit 2: User 3 Status Bit 1: User 2 Status Bit 0: User 1 Status Byte 2 : Bit 7: User 16 Status Bit 6: User 15 Status Bit 5: User 14 Status Bit 4: User 13 Status Bit 3: User 12 Status Bit 2: User 11 Status Bit 1: User 10 Status Bit 0: User 9 Status Byte 3 : Bit 7: User 24 Status Bit 6: User 23 Status Bit 5: User 22 Status Bit 4: User 21 Status Bit 3: User 20 Status Bit 2: User 19 Status Bit 1: User 18 Status Bit 0: User 17 Status Byte 4 (lsb): Bit 7: reserved Bit 6: reserved Bit 5: User 30 Status Bit 4: User 29 Status Bit 3: User 28 Status Bit 2: User 27 Status Bit 1: User 26 Status Bit 0: User 25 Status Values in the range 0 to 4294967103 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_6_4 and is of type INTEGER.

Parameter 7: Alarm Mode

Lock Specific Alarm Mode This configuration setting indicates the Mode of the built-in alarm function of the lock.  The following option values may be configured -:

Value Description
0 Alarm Off
1 Alert
2 Tamper
3 Forced Entry

The manufacturer defined default value is 0 (Alarm Off).

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 8: Alarm Alert Sensitivity

Lock Specific Alarm Alert Sensitivity This configuration setting indicates the sensitivity setting of the Alert function of the built-in alarm.  The following option values may be configured -:

Value Description
1 Most Sensitive
2 More Sensitive
3 Medium Sensitivity
4 Less Sensitive
5 Least Sensitive

The manufacturer defined default value is 3 (Medium Sensitivity).

This parameter has the configuration ID config_8_1 and is of type INTEGER.

Parameter 9: Alarm Tamper Sensitivity

Lock Specific Alarm Tamper Sensitivity This configuration setting indicates the sensitivity setting of the Tamper function of the built-in alarm.  The following option values may be configured -:

Value Description
1 Most Sensitive
2 More Sensitive
3 Medium Sensitivity
4 Less Sensitive
5 Least Sensitive

The manufacturer defined default value is 3 (Medium Sensitivity).

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Parameter 10: Alarm Kick Sensitivity

Lock Specific Alarm Kick Sensitivity This configuration setting indicates the sensitivity setting of the Forced Entry function of the built-in alarm The following option values may be configured -:

Value Description
1 Most Sensitive
2 More Sensitive
3 Medium Sensitivity
4 Less Sensitive
5 Least Sensitive

The manufacturer defined default value is 3 (Medium Sensitivity).

This parameter has the configuration ID config_10_1 and is of type INTEGER.

Parameter 11: Alarm Disable Local Controls

Lock Specific Alarm Disable Local Controls This configuration setting controls the ability to ENABLE or DISABLE local control of the built-in alarm function.  The following option values may be configured -:

Value Description
0 Alarm Disable Local Controls
255 Alarm Enable Local Controls

The manufacturer defined default value is 0 (Alarm Disable Local Controls).

This parameter has the configuration ID config_11_1 and is of type INTEGER.

Parameter 12: Electronic Transition Count

Get Electronic Transition Count This configuration setting indicates the number of transitions from locked to unlocked or unlocked to locked state via electronic activation.  Values in the range 0 to 9999 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_12_4 and is of type INTEGER. This is a read only parameter.

Parameter 13: Mechanical Transition Count

Get Mechanical Transition Count This configuration setting indicates the number of transitions from locked to unlocked or unlocked to locked state via mechanical activation.  Values in the range 0 to 9999 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_13_4 and is of type INTEGER. This is a read only parameter.

Parameter 14: Electronic Failed Count

Get Electronic Failed Count This configuration setting indicates the number of failed electronic activation attempts for this lock Values in the range 0 to 9999 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_14_4 and is of type INTEGER. This is a read only parameter.

Parameter 15: Auto Lock

Automatically throws the deadbolt 30 after seconds This configuration setting controls the lock feature that automatically throws the deadbolt 30 seconds after a valid User Code has been entered at the keypad.  The following option values may be configured -:

Value Description
0 Disable Auto Lock
255 Enable Auto Lock

The manufacturer defined default value is 0 (Disable Auto Lock).

This parameter has the configuration ID config_15_1 and is of type INTEGER.

Parameter 16: User Code PIN Length

Required length of all User Codes This configuration setting controls the length of all User Codes stored in the lock. The values are 4 to 8 with default set to 4.  Values in the range 4 to 8 may be set.

The manufacturer defined default value is 4.

This parameter has the configuration ID config_16_1 and is of type INTEGER.

Parameter 17: Get Electrical High Preload Transition Count

Count of high preload on the deadbolt This configuration setting indicates the number of transitions from locked to unlocked or unlocked to locked state via electronic activation that indicated a high preload on the deadbolt. This value is a subset of Parameter 12. Values in the range 0 to 9999 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_17_4 and is of type INTEGER. This is a read only parameter.

Parameter 18: Get Bootloader Version

Bootloader Version This configuration setting returns the version number of the bootloader in the lock. Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_18_1 and is of type INTEGER. This is a read only parameter.

Lock Timeout

Sets the time after which the door will auto lock.

This parameter has the configuration ID doorlock_timeout and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The BE469ZP supports 1 association group.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. One device controls an other device Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.

Association group 1 supports 2 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_APPLICATION_STATUS_V1
COMMAND_CLASS_SCHEDULE_ENTRY_LOCK_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_DOOR_LOCK_V1
COMMAND_CLASS_USER_CODE_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V8
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_TIME_V1
COMMAND_CLASS_SECURITY_V1

Documentation Links