This page is part of archived documentation for openHAB 2.5. Go to the current stable version

# PLCBus Binding v1

Currently only "One phase mode" of the PLCBus protocol is supported.

# Binding Configuration

This binding can be configured in the file services/plcbus.cfg.

Property Default Required Description
port Yes the name of the serial port you are using to connect, for example /dev/ttyUSB0 or COM1

# Item Configuration

The format of the binding configuration is simple and looks like this:

plcbus="<usercode> <unit> [seconds]"

# Examples

Here are some examples of valid binding configuration strings, as defined in the items configuration file:

Switch Switch1	          "Switch1"          <plcbus> { plcbus="D1 A1"}
Dimmer Dimmer1	          "Dimmer1"          <plcbus> { plcbus="D1 A2 5"}
Rollershutter Rollershutter1  "Rollershutter 1"  <plcbus> { plcbus="D1 A3"}